Toyota Corolla (E120): Inspection procedure

1 Inspect shift solenoid valve(s2)

  1. Remove the shift solenoid valve s2.
  2.  measure the resistance according to the value(s) in the table below.

Standard:

  1. Connect the positive (+) battery lead to the solenoid connector terminal, and the negative (–) battery lead to the solenoid body for checking the solenoid valve operation.

Standard: the solenoid makes an operating noise.

2 Inspect transmission valve body assy(see chapter 2 in the problem

2 Inspect transmission valve body assy(see chapter 2 in the problem symptoms table) (

Repair or replace automatic transaxle assy

Repair or replace automatic transaxle assy

    Share this page:

    Other materials:

    Inspection procedure
    1 Inspect park/neutral position switch assy Disconnect the park/neutral position switch connector.  measure resistance according to the value(s) in the table below when the shift lever is moved to each position. Standard: 2 Check harness and connector(park/neutral position ...

    Removal & installation and disassembly & reassembly
    1. Remove oxygen sensor Remove a clip and tear off the floor mat.  disconnect a oxygen sensor connector. Remove the oxygen sensor. 2. Remove tail pipe assy Remove 2 bolts, 2 springs and tail pipe assy. 3. Remove floor panel brace front Remove 2 nuts and the ...

    Inspection procedure
    1 Input signal check See the input signal check on page 05–745.  check the indicator light when the clutch pedal is depressed. Ok: the indicator light goes off when the clutch pedal is depressed. 2 Inspect terminal voltage(d) Turn the ignition switch to on. &n ...