Toyota Corolla (E120): Short in d squib (2nd step) circuit (to b+)

Dtc b1183/22 short in d squib (2nd step) circuit (to b+)

Share this page:

Other materials:

Inspection procedure
Hint: if different dtcs related to different systems that have terminal e2 as the ground terminal are output simultaneously, terminal e2 may be open. If dtc p0441 (purge flow), p0446 (vsv for ccv), p0451, p0452 or p0453 (evaporative pressure sensor) is output with dtc p0442 or p0456, ...

Fuel pump shut off system
To minimize the risk of fuel leakage when the engine stalls or when an airbag inflates upon collision, the fuel pump shut off system stops the supply of fuel to the engine. Follow the procedure below to restart the engine after the system is activated. ► Vehicles without a smart key syst ...

Oxygen / af sensor heater monitor
Preconditions The monitor will not run unless: mil is off  drive pattern  connect the obd ii scan tool to the dlc3 to check monitor status and preconditions.  Start the engine and allow it to idle for 9 minutes.  Drive the vehicle at 25 mph (40 km ...