1 Prepare for inspection
- Disconnect the negative (–) terminal cable from the battery, and wait at least for 90 seconds.
- remove the horn button assy .
- disconnect the connector of the instrument panel passenger airbag assy .
- disconnect the connector of the front seat airbag assy rh and lh .
- disconnect the connector of the seat belt pretensioner rh and lh .
- disconnect the connectors of the airbag sensor assy center .
- disconnect the connector of the airbag front rh sensor and airbag sensor front lh ( and 60–42).
- disconnect the connector of the side airbag sensor assy rh and lh
- disconnect the connector of the seat position airbag sensor .
Caution
: store the horn button assy, instrument panel passenger airbag assy and front seat airbag assy with the front surface facing upward.
2 Check source voltage
- Connect the negative (–) terminal cable to the battery, and wait at least for 2 seconds.
- turn the ignition switch to on, and wait at least for 60 seconds.
- measure the voltage between e1 (e2) and terminal ig2
on the sensor and operate electric system (defogger, wiper,
headlight, heater blower, etc.).
Ok: voltage: 10 – 14 v
3 Check srs warning light turn off
- Turn the ignition switch to lock.
- disconnect the negative (–) terminal cable from the battery, and wait at least for 90 seconds.
- connect the horn button assy connectors.
- connect the instrument panel passenger airbag assy connector.
- connect the front seat airbag assy rh and lh connectors.
- connect the seat belt pretensioner rh and lh connectors.
- connect the airbag sensor assy center connectors
- connect the front airbag sensor rh and lh connectors.
- connect the side airbag sensor assy rh and lh connectors.
- connect the seat position airbag sensor connector.
- connect the negative (–) terminal cable to the battery.
- turn the ignition switch to on, and wait at least for 60 seconds.
- operate electric system (defogger, wiper headlight, heater blower,
etc.) And check that srs warning
light goes off.
Ok: srs warning light is not light up.
4 Check air bag sensor assy center
Sst 09843–18040
- Turn the ignition switch to lock.
- disconnect the negative (–) terminal cable from the battery, and wait at least for 90 seconds.
- connect the negative (–) terminal cable to the battery, and wait at least for 2 seconds.
- turn the ignition switch to on, and wait at least for 20 seconds.
- clear the dtc stored in memory .
- turn the ignition switch to lock, and wait at least for 20 seconds.
- turn the ignition switch to on, and wait at least for 20 seconds.
- check the dtc .
Ok: dtc is not output.
Use simulation method to check
Other materials:
Inspection
1. Windshield wiper switch assy
Continuity check
check the continuity of each terminal of the connector.
Front wiper switch
Standard:
Front washer switch
Standard:
W/o intermittent time adjust:
intermittent operation check
connect the voltmeter (+) te ...
Inspection and adjustment procedure
1 Tire valve
2 Tire pressure gauge
1 Remove the tire valve cap.
2 Press the tip of the tire pressure gauge onto the tire valve.
3 Read the pressure using the gauge gradations.
4 If the tire inflation pressure is not at the recommended level, adjust the pressure.
If you add too much air, pres ...
Starting the engine
1 Check that the parking brake is set.
► Vehicles without a multi-information display
2 Continuously variable transmission: Check that the shift lever is set in P.
Firmly depress the brake pedal.
Manual transmission: Check that the shift lever is set in N. Firmly depress the
clutch peda ...