Toyota Corolla (E120) 2002–2008 Repair Manual / Diagnostics / Toyota vehicle intrusion protection system / Glass breakage sensor circuit
Toyota Corolla (E120): Glass breakage sensor circuit
Other materials:
Inspection procedure
1 Check p/t squib(rh) circuit(airbag sensor assy center – front
seat outer belt assy rh)
Disconnect the negative (–) terminal cable from the battery,
and wait at least for 90 seconds.
disconnect the connectors between the airbag sensor
assy center and the seat belt pretensio ...
Inspection procedure
1 Inspect terminal voltage(idl)
Remove the cruise control ecu assy with connector still
connected.
disconnect the ecm connector.
turn the ignition switch to on.
measure voltage between terminal 13 (idl) of cruise control
ecu assy connector and body ground when the ...
Inspection procedure
1 Check front airbag sensor (rh) circuit (to b+)(airbag sensor assy
center – airbag front rh sensor)
Disconnect the negative (–) terminal cable from the battery,
and wait at least for 90 seconds.
disconnect the connectors between the airbag front rh
sensor and the airbag sen ...