Circuit description
The p squib (2nd step) circuit consists of the airbag sensor assy center and instrument panel passenger airbag assy. It causes the srs to deploy when the srs deployment conditions are satisfied. Dtc b1185/57 is recorded when a short is detected in the p squib (2nd step) circuit. Wiri ...

Inspection procedure
1 Check side squib(lh) circuit(airbag sensor assy center – front seat airbag assy lh) Disconnect the negative (–) terminal cable from the battery, and wait at least for 90 seconds.  disconnect the connectors between the airbag sensor assy center and the front seat airbag assy ...